Thank you for purchasing HM Digital’s PS-200. The PS-200 is a panel mount total dissolved solids (TDS)
controller that monitors and controls levels of TDS in water. The controller has a maximum set point to
help maintain a limit of TDS allowed in the product water, as well as a second sensor to monitor the TDS
level of the feed water. If the TDS level rises to the set point, the controller will activate a warning light,
sound an alarm (optional) and switch the dry contact position from the normal position (to operate a
valve, pump, etc.). Once the TDS level drops below the set point, this will deactivate the light and alarm
and switch the contacts back to the normal position (normally open or closed). NOTE: The IN mode &
sensor does not have an alarm nor control set point. It is a monitor only.
CONTACT INFO
BOX CONTENTS
SPECIFICATIONS
If you have any problems or questions regarding your controller, please contact HM Digital, Inc.
HM Digital, Inc. [email protected]om
5819 Uplander Way www.tdsmeter.com
Culver City, CA 90230 1-800-383-2777
U.S.A
1. Controller 3. Two sensor cables (grey) 5. Mounting brackets
2. Two sensors (SP-1) 4. Power cord (black) 6. U.S. plug adapter
TDS Range: 0 - 999 ppm (mg/L)
Resolution: 1 ppm
Accuracy: ±2% (of the reading)
Temperature Compensation: Automatic (ATC) (1-60
o
C)
Calibration: Manual by trimmer pot calibration screw
Set-Point: Single point, controlled by on-screen up/down buttons (to any point within the range)
Set-Point Relay: single, isolated, 2A, Max. 220V, resistive load 100,000 strokes
Relay Control (out sensor only): The unit will open or close a circuit via dry contacts when the
ppm level of the OUT sensor (aka product water) reaches or exceeds the control setting (simple
switch). It can be used to control a pump, solenoid valve or other device.
Relay Voltage: 5V (the connected device needs its own power source)
Alarm: Optional steady beep (set by user)
Probe: ½” NPTF bushing
Cable Length: 3 meter (9.8 ft) shielded cable
Display: Bright tri-color L.E.D.
Power Supply: 110V/230V, ±10% Vac; 50/60Hz
Enclosure: Front and back with ABS
Environment: -10 to 50
o
C (4 to 122
o
F); RH max 95% non-condensing
Dimensions: 7.2 x 7.2 x 10.2 cm (2.8 x 2.8 x 4 in.)
Monitor Weight: 476 grams (1 lb 0.8 oz)