Step 1: Install 2 AAA Batteries
as shown in drawing
Step 2: Install Flowmaster on the
product (purified water) line.
Cut tubing and push firmly
into fittings.
1. Press the “Filter” button to light up the LCD screen. The dot should be under filter position
#1. If it is not, push the “Filter” button until the dot is under #1.
2. Program the metering units: Using a small sharp pin or something similar, lightly press the
setting button located above the top right corner of the screen. Press the “Filter” button to toggle
through the four possible metering unit modes. For filter capacities with four digits, set the units
to “gallons”. For filter capacities with five digits, set the units to “gallons x 10”.
3. Program the filter capacity: After programing the units, press the “Setting” button to toggle
through each of the four digits, and set each of the four digits according to the table above.
Press the “Filter” button to increase the number from 0 to 9 while the LCD screen is flashing.
4. The Flowmaster will memorize the setting automatically after pausing for 5 seconds.
5. Note the four bars on the left hand side of the screen which show that the setting was stored
sucessfully.
6. There is an option to program the “Monthly Lifetime Setting”. However, this application does
not require this option. PLEASE SKIP THIS SETTING.
7. Resetting the unit: After the filter capacity has reached it’s set life, a buzzer will sound to
alert the user to replace the filter. After replacing the filter, press the “Reset” button. The
accumulated number of gallons will be reset to zero and a new filter life begins.
Programing the Flowmaster:
Stealth-RO100 & Stealth-RO200 1,250
Stealth-RO100 & Stealth-RO200 w/KDF 2,000
Triton-RO/DI200 & Triton-RO/DI200 2,000
Triton-RO/DI200 & Triton-RO/DI200 w/KDF 3,250
Filter Capacity Gallons
2. There is a possibility of
programming 6 dierent
lter capacities. Use only
lter position #1 for this
application.
**** PLEASE NOTE ****
1. You only have 5 seconds
between each step, or the
screen will go blank.
- See Reverse -
PURIFICATION SYSTEMS
For Use With: Stealth-RO100 & RO200, Triton-RO/DI100 & RO/DI200 and most other RO systems
1/4” FLOW MASTER Digital Flow Meter Manual
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - Programing the Flowmaster:

Step 1: Install 2 AAA Batteries as shown in drawingStep 2: Install Flowmaster on the product (purified water) line.

Pagina 2 - PURIFICATION SYSTEMS

FLOW MASTER Programing Example WARNING: 1. This product is pressure sensitive. Changes in water pressure

Comentarios a estos manuales

Sin comentarios